用户工具

站点工具


edastudy:tessent:dft_signals

这是本文档旧的修订版!


1. dft signals

table_1 table_2 table_3 list the pre-registered static DFT signals.

table_4 Table 4 lists the pre-registered dynamic DFT signals.

1.1 Table 1

Pre-Registered Static Global DFT Control Signal Names
all_test
bscan_clamp_enable
bscan_input_isolation_enable
output_pad_disable
dft_signal_disable
occ_kill_clock_en
ssn_en
tck_occ_en
tck_select
tristate_enable_nc_test
tristate_enable_nc_test_type

1.2 Table 2

Pre-Registered Static Logic Test Control Signal Names
async_set_reset_static _disable
capture_per_cycle_static_en
control_test_point_en
ext_ltest_en
ext_lbist_en
int_ltest_en
lbist_en
lbist_low_power_shift_en
lbist_self_test_en
ltest_en
mcp_bounding_en
memory_bypass_en
observe_test_point_en
se_pipeline_en
wrapper_toggle_en
x_bounding_en

1.3 Table 3

Pre-Registered Static Scan Mode Signal Names
controller_chain_mode
edt_mode
ext_edt_mode
ext_mode
ext_multi_mode
ext_single_mode
int_edt_mode
int_mode
int_multi_mode
int_single_mode
multi_mode
promoted_cells_mode
retargeting#_mode = 1, 2, ...,8
single_mode

1.4 Table 4

Pre-Registered Dynamic DFT Signal Names
async_set_reset_dynamic_disable
capture_per_cycle_dynamic_en
edt_clock
edt_update
input_wrapper_scan_en
lbist_async_set_reset_dynamic_enable
lbist_misr_accumulate_en
lbist_prpg_en
lbist_reset
output_wrapper_scan_en
scan_en
shift_capture_clock
shift_clock
capture_clock
test_clock

1.4.1 async_set_reset_dynamic_disable

1.4.2 edt_clock

1.4.3 shift_capture_clock

1.4.4 shift_clock

1.4.5 capture_clock

2. wavefroms

3. connection

edastudy/tessent/dft_signals.1708304554.txt.gz · 最后更改: 2024/02/19 09:02 由 zhangguo

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki