用户工具

站点工具


edastudy:tessent:atpg

差别

这里会显示出您选择的修订版和当前版本之间的差别。

到此差别页面的链接

两侧同时换到之前的修订记录前一修订版
edastudy:tessent:atpg [2026/07/06 19:14] – [2.2 low power shift & capture] user01edastudy:tessent:atpg [2026/07/06 19:14] (当前版本) – [3. X-bounding] user01
行 138: 行 138:
 如果报 如果报
 <code> <code>
-// Warning: Could not identify the data path input for the library cell containing// the memory element at /dff115/D (382.4). X-bounding logic cannot be inserted in// the scan path so this is a fatal error. This could be caused by missing// pin constraints and/or scan_enable connections. (XB2-1)+// Warning: Could not identify the data path input for the library cell containing 
 +// the memory element at /dff115/D (382.4). X-bounding logic cannot be inserted in 
 +// the scan path so this is a fatal error. This could be caused by missing 
 +// pin constraints and/or scan_enable connections. (XB2-1)
 </code> </code>
 一个解法是给对应的register cell换成带scan cell的,要么把它的SE悬空,要么把它case为1,即能在它前面正常插入x-bounding. 一个解法是给对应的register cell换成带scan cell的,要么把它的SE悬空,要么把它case为1,即能在它前面正常插入x-bounding.